Posital dual axis inclinometer ± 80° with 4-20mA output
| Order Code: | ADS-080-2-AC00-HE2-CW |
|
E-mail this page |
|
Print this page | | Download PDF file | | | | Packaging: | 1 | Min. Order: | 1 | Supplier: | Posital Fraba B.V. | |
You are not logged in. Please Login or register to view prices and order online.
Description of PDF file: Posital Tilt Catalogue complete with meters and cables |
Order Code Builder :
Posital Fraba B.V. offers user selectable variants and/or options. Dynamically build order-codes and initiate a Quotation Request.
- Posital Analogue TILTIX Inclinometers - This Order Code Builder is for single and dual axis static inclinometers with (voltage or current output) OR with (voltage or current + RS232 output).
- Posital Digital TILTIX inclinometers - This Order Code Builder is for single and dual axis static and dynamic inclinometers with digital outputs (including RS232, Binary or Gray code, CANOpen, SAE J1939, DeviceNet or Modbus RTU)
Description: Posital's MEMS inclinometers are manufactured in 4 different housings and service 3 different markets.
The markets are:
1) Static inclinometers measuring gravitation tilt on platforms etc that are not subject to rotational forces.
2) Dynamic inclinometers that incorporate a gyroscope that is used to offset rotational acceleration and provide more accurate inclination on farm, forestry and construction machine subject to irregular movements.
3) Carefully designed and constructed inclinometers with ATEX specifications required by oil, gas, mining and chemical industries.
In addition a roll and tilt unit is available.
The attached PDF file includes details of these features and information on cables and associated panel meters.
The ADS-080-2-AC00-HE2-CW is a Posital dual axis inclinometer for ±80° with 0.5° accuracy, 0.01° resolution, 10-30Vdc supply with max of 270Ω load@10Vdc, 500Ω load@15Vdc, with reverse polarity protection (power supply range), short circuit protection.
General Specifications | |
---|
Application | 2-Axis Position Monitoring and Levelling | Measurement Range | ±80° | Absolute Accuracy | 0.5° | Resolution | 0.01° |
Electrical Specifications | |
---|
Supply Voltage | 10-30 VDC (See also Interface="Max Load Resistance") |
Power Consumption (no load) | ≤0.7 W | EMC="Emitted Interference" | DIN EN 61000-6-4 | EMC="Noise Immunity" | DIN EN 61000-6-2 | Reverse Polarity Protection | Yes | Short Circuit Protection | Yes |
Environmental Specifications | |
---|
Operating Temperature | -30°C fixed (-22°F), -5°C flexible (+23°F) - +70°C (+158°F) | Storage Temperature | -40°C (-40°F) to +85°C (+185°F) | Temperature Gradient | 0.004°/K | Protection Class | IP66/IP67 | Shock Resistance | ≤100g (half sine 6 ms, EN 60068-2-27) | Vibration Resistance | 1.5 mm (10 Hz to 58 Hz) ≤20 g (58 Hz to 2000 Hz) |
Mechanical Specifications | |
---|
Housing Material | Fibre-Reinforced PBT (Polybutylene Terephthalate) | Potting Material | PUR (Polyurethane) | Weight | 170 g (0.37 lb) |
Certificates/Lifetime | |
---|
MTTF | 350 years @ 40°C | Certificates | CE |
Interface | |
---|
Interface | Analog Current 4-20 mA | Settling Time | 125 ms | Output Type | Current 4-20 mA | Max Load Resistance | 270 Ω@10Vdc, 500Ω@15Vdc | Linearity | ±0.02% |
|