SGP series, 500mm, 4-20mA ouput |
SIKO Wire Actuator, 500mm, stainless steel wire, Type 01, 10K potentiometer, with intrument transformer (4-20mA) |
Order Code:SGP-500-S-01-10-M |  | SIKO SGx family of wire actuators are universally applicable designs, with precise and safe cable guidance systems, robust Aluminium housing and strong mounting flange.
Three measuring systems provide a combination of convenience and high accuracy.
1) SGP series with Potentiometer,
2) SGI series with Incremental Encoder,
3) SGW series with Absolute Encoder,
Measuring range is 250mm to 6000mm.
Draw wire types:
S Stainless steel (6000mm max) (our standard design)
SK Plastic coated steel wire (4000mm max) ( 2 times more tear-resistant than steel cable)
P para-line non-conducting synthetic line (2750mm max) (4 times more tear resistant than steel cables)
SGP Series with potentiometer
Electrical: via terminal block in casing.
Potentiometer values: 1, 2, 5, 10K
< 500 mm Type 01: Resistance tolerance ±10%, linearity ±1% Max Load=2W @T = 40°Cmax
> 500 mm Type 02: Resistance tolerance ±5%, linearity ±0.25% Max Load=1W @T = 40°Cmax
> 500 mm Type 03: Resistance tolerance ±5%, linearity ±0.25% Max Load=2W @T = 40°Cmax
3 wire interconnection for poteniometer models.
Optional 4-20mA
4-20mA, 2 wire interface via an instrument transformer for models using 10K pot. Internal start and end point adjustments using trimming potentiometers. M=with / X=without.
Display Meter: eg SIKO MA50
SGI Series with incremental encoder
Standard Encoder: IV58-003
Operating Voltage: 24Vdc @ 70mA
Output circuit: PP
Output Signal: ABO
Resolution: 10 pulses / mm
Electrical cable: 1m
Protection Class: IP54
Display meter: eg SIKO Model 10/4 with PP inputs
SGW Series with absolute encoder
Standard Encoder: MV58-0001
Operating Voltage: 24Vdc @ 30mA
Steps per revolution: 4096 (12bit) at 204.8mm drum circumference
Output Signal: SSI
Resolution: 1 bit = 0.05mm
Electrical cable: 1m
Protection Class: IP54
Display meter: eg SIKO Model 10/4 with SSI inputs
Options:
• Choice of draw wire cable
• Extension to draw wire cable.
• 1 or 2 limit switches.
Accessories
• Model UR, guide wheels.
• Model SV, cable extension fitting.
Application recommendations :
• The wire should be pulled out straight to avoid wear (else use guide roller UR).
• The wire must not freely snap back into the housing.
• Recommend starting measurement with 5mm cable extension.
| |

|
| |
Supplier: | SIKO GMBH |
Packaging: | 1 |
Min. Order: | 1 |
|
|